+Advanced Search 中文版
Experimental study on pylon segment model of Sanguan Hanjiang low pylon cable-stayed bridge
Author:
Affiliation:

(Liuzhou OVM Machinery Co., Ltd., Liuzhou 545005,China)

Clc Number:

U446.1

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    By combining finite element analysis with cable tower model test, the stress analysis of the tower anchorage area of the low pylon cable-stayed bridge in Sanguan Hanjiang Highway, Wuhan City, was carried out to verify the static load and anti-slip performance of the single-sided bidirectional anti-slip device of the cable tower anchorage zone. The cable replacement process of a single steel strand in the operation stage of the real bridge was simulated by test, which provided technical support for design and construction. The test results show that the structure of the cable pylon anchorage area of the bridge is safe under stress, the anti-slip structure of the cable pylon anchorage area and the cable changing process of a single steel strand meet the design and specification requirements.

    Reference
    Related
    Cited by
引用本文

Min Qiu, Ningtuo Gao, Weiwei Qin, Qiang Song, Wenwen Li, Jun Hu, Wenqin Deng, Bo Xie Experimental study on pylon segment model of Sanguan Hanjiang low pylon cable-stayed bridge. Prestress Technology 2014,18(05):11-18. 10.59238/j. pt.2014.05.003

复制
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: August 06,2023
  • Published: