+Advanced Search 中文版
Design of prestressed wide flat beams for Chongqing Langgao Hyatt Hotel
Author:
Affiliation:

(1.College of Civil Engineering, Chongqing University;2. Chongqing Design Institute;)

Clc Number:

TU757

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    This article briefly introduces the design characteristics of bonded prestressed flat beams for the Chongqing Langgao Hyatt Hotel project. In the design, the finite element program is used to analyze the influence of beam column stiffness on the axial preload of the beam. By reserving post pouring strips for columns and walls, the constraint effect of vertical components on prestressed beams is reduced, and the secondary axial force in the beams is reduced, making the design economical and reasonable. It has certain reference value for similar engineering designs

    Reference
    Related
    Cited by
引用本文

Wu Shengda, Qin Shihong, Li Tangning, Gao Shun, Li Ling Design of prestressed wide flat beams for Chongqing Langgao Hyatt Hotel. Prestress Technology 2008,12(01):8-12. 10.59238/j. pt.2008.01.002

复制
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: August 10,2023
  • Published: