    摘要:

    本文旨在通过对上海市某工程拆除的预制拼装桥墩灌浆套筒进行剖切检测,分析其施工质量及潜在缺陷的影响。研究采用剖切检测方法,对10个灌浆套筒样本的灌浆密实度、钢筋锚固长度及居中度等关键指标进行详细分析。结果表明,灌浆套筒的灌浆料密实度良好,各项受力性能均符合规范和设计要求,施工质量总体可靠。尽管局部钢筋锚固长度略短、钢筋居中度存在一定偏差,但根据现有研究,对构件的承载能力和变形能力影响可忽略不计。研究认为,现行施工工艺基本能满足施工质量要求,但建议优化灌浆料配置、改进施工工艺,并增加套筒外壁螺纹构造以增强与混凝土的握裹力。本研究为灌浆套筒连接墩柱的安全性、耐久性提供了实际工程案例的试验数据支撑,旨在补充无损检测方法难以发现的内部缺陷信息。

    Abstract:

    This study investigates the construction quality and potential defects of grouted sleeve connections in a prefabricated bridge pier dismantled from a project in Shanghai using section-cutting inspection. Ten samples were examined with a focus on grout compactness, reinforcement anchorage length, and centering accuracy. The results show that the grout within the sleeves was highly compact, and all mechanical performance indices satisfied the relevant specifications and design requirements, indicating overall reliable construction quality. Minor deficiencies, including slightly insufficient anchorage length and deviations in reinforcement centering, were identified but are considered to have negligible effects on load-bearing and deformation capacities on the basis of existing research. The findings suggest that the current construction process generally meets quality requirements; however, improvements in grout mix proportion, construction procedures, and the addition of external threading on the sleeve surface are recommended to enhance bonding with surrounding concrete. This work provides experimental evidence from an actual engineering case to support the safety and durability assessment of grouted sleeve–connected piers and supplements nondestructive testing by revealing internal defects that are otherwise difficult to detect.