+高级检索 English
OVM250钢绞线拉索锚具水密性试验研究
作者:
作者单位:

(柳州欧维姆机械股份有限公司,柳州 545005)

作者简介:

闫云友

通讯作者:

中图分类号:

U663.8

基金项目:


Test study on watertightness of OVM250 steel strand cable anchor
Author:
Affiliation:

(Liuzhou OVM Machinery Co., Ltd., Liuzhou 545005,China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    本文主要介绍了OVM250拉索体系产品的水密性试验研究情况,通过对国际三大斜拉索规范PTI2007、fib2005和CIP2002对斜拉索体系产品水密性的试验要求的对比,结合钢绞线斜拉索的实际使用工况,综合考虑了fib2005和CIP2002两大规范对拉索产品水密性试验要求,各种试验参数取两大规范中的高要求,试验水压参数按fib2005要求的3m水压,试验装置按倾斜30度安装和试验周期6个星期按CIP2002规范。因国内外有资质的实验室没有相应的试验设备,OVM公司按确定的试验参数及CIP2002规范试验安装要求设计加工了试验装置并配套试验设备,在国家建筑工程质量监督检验中心及美国CTL实验室的双重见证下进行了水密性试验,并圆满成功,该水密性试验充分验证了OVM250钢绞线拉索锚具的密封可靠性。

    Abstract:

    This paper mainly introduces the watertightness test of OVM250 cable system products. By comparing the watertightness test requirements of the three major international cable standards PTI2007, fib2005 and CIP2002, combined with the actual working conditions of the steel cable stays, fib2005 and CIP200 are considered 2 The two codes require the watertightness test of cable products, and the various test parameters are the highest requirements in the two codes. The test water pressure parameters are 3m water pressure as required by fib2005, the test device is installed at a tilt of 30 degrees and the test period is 6 weeks according to CIP2002 specifications. Due to the lack of corresponding test equipment in qualified laboratories at home and abroad,OVM company designed and processed the test equipment and supporting test equipment according to the determined test parameters and CIP2002 standard test installation requirements. Under the double witness of the National Construction Engineering Quality Supervision and Inspection Center and the United States CTL laboratory, the watertightness test was carried out successfully, and the watertightness test was sufficient The sealing reliability of OVM250 cable anchor is verified.

    参考文献
    相似文献
    引证文献
引用本文

Yunyou Yan, Yanhua Tang, Yongjiu Huang, Jianguo Chen, Qi Qi Test study on watertightness of OVM250 steel strand cable anchor. Prestress Technology 2014,18(03):9-12. 10.59238/j. pt.2014.03.002

复制
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-08-08
  • 出版日期: